Line Interval & DPI
0.030 mm· 30.0 µm
Spot overlap: 6% on 32 µm beam
xTool F1 Ultra · 20W Fiber Brass Planner
Dial in 20W 1064 nm fiber emboss slices, line interval, and cleanup cadence for C360 brass coins and jewelry blanks on the xTool F1 Ultra 220 × 220 mm galvo field.
100% Local Browser Calculator · Free
Pre-configured machine & material profile
xTool Creative Space (XCS) Emboss Mode or LightBurn GalvoShop note: Focus sharply on the blank surface and re-check Z focus every 0.8–1.0 mm on deep coins.
Quick starting presets
Line Interval & DPI
0.030 mm· 30.0 µm
Spot overlap: 6% on 32 µm beam
Depth Removed Per Slice
5.6 µm
198 total passes (180 slices + 18 cleanup)
Estimated Cycle Time
101 min
Based on 1200 mm/s across 40 mm area
8-Bit Banding Risk
HIGH· Use true 16-bit PNG
256+ slices require genuine 16-bit gradients to prevent concentric rings.
Ready to turn a photo into this exact relief?
Preview 3D coin separation free in browser; export forward and inverted true 16-bit PNGs tuned for xTool Emboss and LightBurn. Failed jobs never lose credits, purchased credit packs never expire, and commercial client carving rights are included.
| Blank style | Target depth | Slice layers | Line interval | Est. cleanup cadence |
|---|---|---|---|---|
| 25–30 mm Brass Tag | 0.5–0.8 mm | 96–140 layers | 0.025 mm (1016 DPI) | Every 10–12 layers |
| 40 mm Challenge Coin | 0.9–1.3 mm | 160–220 layers | 0.030 mm (846 DPI) | Every 8–10 layers |
| 40 mm High-Relief Coin | 1.4–1.6 mm | 240–280 layers | 0.030 mm (846 DPI) | Every 8 layers + mid-refocus |
| Brass Wax Seal Stamp | 1.1–1.5 mm | 180–240 layers | 0.025–0.030 mm | Every 10 layers (inverted map) |
The xTool F1 Ultra pairs a 20W 1064 nm fiber source with a fine ~30 micron central spot, giving impressive micro-detail on 25 mm to 45 mm brass coins and wax seal stamps. Because 20W delivers lower peak pulse energy than a 60W MOPA benchtop unit, each pass removes roughly 4 to 6 microns of C360 brass rather than 10+ microns.
Planning realistic slice counts between 128 and 256 layers keeps run times predictable and avoids chasing 2.5 mm depths where beam defocus and wall taper start rounding off fine lettering.
Without periodic high-speed cleaning passes, vaporized zinc and copper condense on the relief slopes and form a stubborn dark crust that blocks subsequent 20W pulses. Scheduling a cleaning pass every 8 to 12 slices—paired with active fume extraction right across the coin surface—keeps the bottom floor bright and evenly ablated.
Keep brass blanks centered inside the inner 100 × 100 mm zone of the 220 × 220 mm F-theta lens so beam incidence stays nearly perpendicular and sidewalls do not lean outward.
xTool Creative Space Emboss mode slices a grayscale depth image sequentially from white to black. Feed it an 8-bit web JPEG with compression halos and you will etch permanent concentric rings into your brass blank that steel wool cannot polish away.
Preview your coin rim, background floor, and subject elevation free inside DepthCarve, then unlock a single-credit production bundle with forward and inverted true 16-bit PNGs so you can carve raised coins or recessed wax seal dies from the same job.
Always select the 20W 1064 nm fiber (IR) source for bare brass coins and pendants. The 20W 455 nm blue diode cannot ablate raw brass cleanly for multi-layer 3D depth relief.
A 40 mm brass coin at 1.0 to 1.3 mm depth with 180 to 220 layers at 846 DPI typically runs 45 to 85 minutes including periodic cleaning passes, depending on scan speed and filled artwork area.
For shallow reliefs up to 0.8 mm, a single sharp focus on the blank face works well. Once you push past 1.2 mm depth on a 20W source, dropping focus by 0.4 to 0.5 mm halfway through restores crisp wall ablation.
Yes. Every DepthCarve production bundle includes both forward and inverted true 16-bit PNGs, so you can load the recessed polarity directly for brass wax stamps without re-inverting in an image editor.