Skip to content
DepthCarve

Gweike G2 20W Fiber · Brass Coin Planner

Gweike G2 20W brass coin calculator for 3D challenge coins

Optimize compact 20W 1064 nm fiber galvo passes on the Gweike G2 (110 × 110 mm field) for 38–40 mm brass challenge coins, pendants, and wax seal stamps without overheating the head.

100% Local Browser Calculator · Free

Interactive parameters & live geometry output

Pre-configured machine & material profile

GLaser / LightBurn Galvo (on G2 Pro / LightBurn-supported board)
Machine
Gweike G2 / G2 Pro (20W 1064 nm Portable Fiber Galvo)
Target Material
C360 / C260 Brass Coin & Wax Stamp Blanks (25–40 mm)
Power / Optics / Tooling
20W 1064 nm Pulsed Fiber · 110 × 110 mm lens (~30–35 µm spot)
Work Envelope
110 × 110 mm F-theta field (ideal fluence density for 20W)
Speed / Feed Envelope
Up to 15,000 mm/s max · 900–1,600 mm/s 20W brass 3D relief
Starting Reference
95–100% power · 30–40 kHz · 846–1016 DPI · +15° angle step · cleanup every 10 passes

Shop note: Use the built-in dual red-dot focus pointer precisely on the coin surface and re-focus down 0.4 mm halfway through 1.2 mm+ coins.

Quick starting presets

Inputs

Calculated shop readout

Line Interval & DPI

0.030 mm· 30.0 µm

Spot overlap: 9% on 33 µm beam

Depth Removed Per Slice

5.0 µm

198 total passes (180 slices + 18 cleanup)

Estimated Cycle Time

110 min

Based on 1100 mm/s across 40 mm area

8-Bit Banding Risk

HIGH· Use true 16-bit PNG

256+ slices require genuine 16-bit gradients to prevent concentric rings.

Ready to turn a photo into this exact relief?

Preview 3D geometry free · Export true 16-bit PNG + EXR + watertight STL

Preview 3D coin and wax-stamp relief free; export forward & inverted true 16-bit PNGs from $0.40/job. Failed jobs never lose credits, purchased credit packs never expire, and commercial client carving rights are included.

Gweike G2 20W fiber brass 3D relief starting benchmarks

Brass itemTarget Z-depthSlice layersDPI (line spacing)Est. runtime
25 mm Wax Seal Die0.9–1.2 mm160–220 slices1016 DPI (0.025 mm)22–38 min (inverted map)
38–40 mm Coin (std)0.8–1.1 mm160–200 slices846 DPI (0.030 mm)42–65 min
40 mm Deep Coin1.2–1.5 mm240–280 slices846 DPI (0.030 mm)65–95 min + mid refocus

Why the Gweike G2 110 mm lens punches above its 20W rating on coins

Many compact 20W fiber units ship with oversized lenses that dilute energy density. Because the Gweike G2 focuses its 20W 1064 nm beam across a tight 110 × 110 mm field (~30–35 micron spot), single-pulse fluence comfortably clears brass's ablation threshold for genuine 3D reliefs.

Plan on roughly 4 to 5.5 microns removed per slice, meaning 180 to 256 layers reliably sculpt a tactile 0.9 to 1.4 mm coin relief with razor-sharp lettering.

Keeping 20W brass runs clean with periodic slag-clearing passes

At 20W average power, dark brass oxide slag builds up quickly if you skip cleaning passes—choking off ablation after slice 80. Interleaving a fast cleaning pass (2,500 mm/s, high frequency) every 8 to 10 slices keeps the coin floor bright and preserves consistent depth per slice.

Always place a small desktop fume nozzle right beside the coin blank so vaporized zinc does not re-deposit on the protective lens window.

Carving brass wax seal stamps with inverted 16-bit depth maps

Twenty-five millimeter brass wax seal dies are one of the highest-margin products for a 20W Gweike G2—finishing in roughly 25 to 35 minutes with dramatic 3D wax impressions.

Every DepthCarve production export includes both forward (raised coin) and inverted (recessed wax stamp) true 16-bit PNGs from a single free-to-preview job.

Frequently asked questions

Can the Gweike G2 20W carve true 3D brass challenge coins?

Yes. Using 160 to 256 slices at 846 to 1016 DPI and 95–100% power, a 20W Gweike G2 carves crisp 0.9 to 1.4 mm 3D reliefs in 38–40 mm brass coin blanks.

How does the Gweike G2 20W compare to a 60W MOPA on 40 mm brass coins?

Detail quality is nearly identical on a 110 mm lens, but the 20W source takes roughly twice as long (50–85 minutes vs 25–35 minutes) for the same 1.3 mm depth.

Do I need to lower focus midway on a 20W brass coin?

For reliefs deeper than 1.0 mm, lowering the Z column by 0.4 to 0.5 mm halfway through keeps the beam waist tightly focused at the deeper coin floor.

What image format avoids terraced rings on 200+ slice Gweike G2 runs?

Always start from a true 16-bit grayscale PNG depth map rather than a compressed 8-bit JPEG so smooth domed surfaces ablate without visible staircase contours.